logo
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Flow Meter > CAFS1000C Flow Range 10-800 KG / H Flow Rate Sensor Customizable Service Voltage 14V DC

CAFS1000C Flow Range 10-800 KG / H Flow Rate Sensor Customizable Service Voltage 14V DC

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Model Number: CAFS1000C

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline conversation or face-to-face discussion

Delivery Time: 3-7 work days

Payment Terms: L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments

Supply Ability: 999

Get Best Price
Highlight:

10KG / H flow rate sensor

,

800 KG / H flow rate sensor

,

14V DC air flow meter

Customizable Service Voltage:
14 VDC
Accuracy:
±2.0% FS
Maximum Pressure:
0.3MPa
Output Method:
Frequency Output Ranges From 2.05 To 11.69KHz Analog Outputs Of 1-5V Selectable
Flow Range:
10-800Kg/h Customizable
Calibration Method:
Air, And The 20℃,101.325kPa
Customizable Service Voltage:
14 VDC
Accuracy:
±2.0% FS
Maximum Pressure:
0.3MPa
Output Method:
Frequency Output Ranges From 2.05 To 11.69KHz Analog Outputs Of 1-5V Selectable
Flow Range:
10-800Kg/h Customizable
Calibration Method:
Air, And The 20℃,101.325kPa
CAFS1000C Flow Range 10-800 KG / H Flow Rate Sensor Customizable Service Voltage 14V DC

 

 

For the best solution to meet your specific needs, please reach out to us with your requirements!

CAFS1000C Flow Range 10-800 KG / H Flow Rate Sensor Customizable Service Voltage 14V DC 0

■ High accuracy (± 2.0%F. S accuracy)

■ Linear output and no temperature compensation

■ Maintain long-term stability with minimal zero-drift

■ Quick response time (20 ms response time)

■ The flow rate range is 0-60 m/s wide, and the strong impact resistance is 100g

■ Solid-state sensing core (no surface cavity or fragile film), resistance to blockage and pressure impact

■ Output mode: analog voltage output (1 to 5V), frequency output (2.05~11.69KHZ), two options

■ Reliability, can be adapted to the relatively wet gas measurement

■ Operating temperature: -40°C to 125°C, storage temperature: -40°C to 125°C, humidity: 0100% RH

■ The sensor is resistant to condensate water

 

 

Functional items

CAFS1000C Flow range 10-800Kg/h customizable service voltage14 VDC
performance parameter unit remarks
Flow range 10-800 Kg/h customizable
service voltage 14 VDC  
accuracy ±2.0 % FS  
repetitiveness <0.5 %  
response time 20 ms selectable
maximum pressure 0.3 MPa  

 

Output method

Frequency output ranges from 2.05 to 11.69

Analog outputs of 1-5

KHz

 

V

 

selectable

temperature -40~125  
levels of protection IP40  
Calibration method Air, and the 20℃,101.325kPa
The overall material ABS