Send Message
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Flow Controller > CAFS5012E Multiple types of output are available: analog output (15 V), I2C or RS485

CAFS5012E Multiple types of output are available: analog output (15 V), I2C or RS485

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Certification: PTC23041812701C-CN01

Model Number: CAFS5012E

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline conversation or face-to-face discussion

Delivery Time: 3-7 work days

Payment Terms: L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments

Supply Ability: 999

Get Best Price
Highlight:
Explosion-proof Type:
Ex Ia IIC T6 Ga
Temperature:
Medium Temperature(-10~65)℃,Ambient Temperature (-25~85)℃
Flow Range:
0-50,80,100,150,200,250,300,400SLPMCustomizable
Precision:
±1.5%F.S
Explosion-proof Type:
Ex Ia IIC T6 Ga
Temperature:
Medium Temperature(-10~65)℃,Ambient Temperature (-25~85)℃
Flow Range:
0-50,80,100,150,200,250,300,400SLPMCustomizable
Precision:
±1.5%F.S
CAFS5012E Multiple types of output are available: analog output (15 V), I2C or RS485

 

 

Product Presentation: CAFS5012E Explosion-Proof Gas Mass Flowmeter

Overview

The CAFS5012E Explosion-proof Gas Mass Flowmeter utilizes advanced microelectromechanical system (MEMS) flow sensor chip technology, making it suitable for clean and relatively dry gas flow measurement and process control. Its unique packaging technology allows for a wide range of flow measurement capabilities, ensuring high sensitivity, reliability, stability, and cost-effectiveness.

Key Features

  • MEMS Flow Sensing Unit: High precision digital processing and calibration circuit (MCU) for accurate flow measurement.
  • Integrated Technology: Includes Δ - Σ A/D converter, logic circuit with internal calibration, and MCU processor for real-time signal acquisition and compensation.
  • Self-Calibration: No external calibration needed, ensuring high precision flow output.
  • Protection Circuits: Includes power system, connection, and port protection circuits.
  • Digital Output Communication: Easy data communication through digital output modes.

Performance Parameters

Functional Items CAFS5012E Series Explosion-Proof Medical Flowmeters
Flow Range 0-50, 80, 100, 150, 200, 250, 300, 400 SLPM (Customizable)
Power Supply 8~24VDC, 50mA
Explosion-Proof Type Ex ia IIC T6 Ga
Precision ±1.5 %F.S.
Response Time 10, 20, 65, 150 ms (factory default 65, customizable)
Maximum Pressure 0.8 MPa (Customizable)
Output Mode Analog output 1-5V, digital RS485 or I2C (optional)
Temperature Medium temperature: -1065℃, Ambient temperature: -2585℃
Interface G1/2 (Customizable)
Calibration Method Air, 20°C, 101.325kPa
Overall Material Aluminum alloy (stainless steel customizable)

Precautions

  1. Read Manual: Carefully read the manual before using the product.
  2. Environment Suitability: Best used in clean gas environments; not suitable for dusty, oily, or multiphase flow environments without prior consultation.
  3. Application Scope: Suitable for gas measurement, monitoring, and control in various industries. Use in unsuitable environments should be controlled.
  4. Follow Safety Procedures: Adhere to relevant operating specifications and safety precautions.
  5. Liability: Wuxi Consensk Electronic Technology Co., Ltd. and its affiliates are not liable for damages from improper use. Refer to the sales contract for other matters.

Matters Needing Attention

  1. Defined Environment: Ensure the product works within the defined environment.
  2. Installation: Follow gas flow marks during installation and conduct connection and leakage detection as per regulations.
  3. Impurities: Avoid online installation or cleaning operations that may introduce impurities and damage the product.
  4. Water Exposure: Avoid exposure to water as it may damage the sensor's sensitivity.
  5. Power Supply: Correctly connect the positive and negative electrodes to prevent internal circuit damage.

Differentiation

The CAFS5012E stands out due to its integration of MEMS technology, high precision calibration, and robust protection features, making it a reliable and efficient choice for a wide range of gas flow measurement applications in industrial, medical, and commercial fields.