Send Message
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Medical Pressure Sensors > 4.5 X 4.5 X 3.5mm Medical Pressure Transducer Weather Stations GPS Applications

4.5 X 4.5 X 3.5mm Medical Pressure Transducer Weather Stations GPS Applications

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Model Number: CPS135B

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline contact or face-to-face discussion can be negotiated

Delivery Time: 3-7 work days

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram/Alipay/business-to-business

Supply Ability: 1000pcs

Get Best Price
Highlight:

medical pressure transducer weather stations

,

4.5 x 4.5 x 3.5mm medical pressure transducer

,

weather stations pressure transducer medical device

Solder Drifts:
±0.2kpa
Pressure Accuracy:
±0.3kPa (±3.0mbar) @ 25°C
Temperature Accuracy:
±1.0°C
Accuracy:
-40°C To 85°C
Solder Drifts:
±0.2kpa
Pressure Accuracy:
±0.3kPa (±3.0mbar) @ 25°C
Temperature Accuracy:
±1.0°C
Accuracy:
-40°C To 85°C
4.5 X 4.5 X 3.5mm Medical Pressure Transducer Weather Stations GPS Applications

CPS135B Pressure Accuracy: ±0.3kPa (±3.0mbar) @ 25°C Temperature Accuracy: ±1.0°C

 

Physical Characteristics

  • Small Form Factor, 4.5 x 4.5 x 3.5mm (w x l x h)

  • SMD, 6 Lead

  • Ceramic Substrate

 

Applications

  • Altimeters
  • Portable and Stationary Barometers
  • Weather Stations
  • GPS Applications
  • Hard Disk Drives(HDD)
  • Industrial Equipment
  • Air Control Systems
  • Vacuum Systems

 

Performance parameters

PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
PRESSURE SENSOR
Range    

50

(500)

 

160

(1600)

kPa

(mbar)

Resolution1      

0.01

(0.1)

 

kPa

(mbar)

Accuracy  

50 to 160kPa

@25°C

-0.3

(-3.0)

±0.15

(±1.5)

+0.3

(+3.0)

kPa

(mbar)

 

50 to 160kPa

(0°C to 50°C Verified)

-0.5

(-5.0)

±0.3

(±3.0)

+0.5

(+5.0)

kPa

(mbar)

Solder Drifts     -0.2   +0.2 kPa
TEMPERATURE SENSOR
Range     -40   85 °C
Resolution       0.003   °C
Accuracy   -40°C to 85°C -1 ±0.75 +1 °C
OPERATION
Supply Voltage to GND2 VSUPPLY   2 3.0 5.5 V
Operating Temperature Range     -40   85 °C
I2C Pull-Up Resistors RPU   1 2.2   kΩ

1Guaranteed by design of 24bits ADC, and calculated according to the range in application.

2 Factory calibrated for Pressure and Temperature at 3.0V±10%. Output accuracy will be affected if used outside this range. Other ranges available upon request.