Send Message
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Flow Controller > 20ms Response Time Air Flow Controller Analog Output 1 To 5V

20ms Response Time Air Flow Controller Analog Output 1 To 5V

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Certification: PTC23040404901C-CN01

Model Number: CAFS4000

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline conversation or face-to-face discussion

Delivery Time: 3-7 work days

Payment Terms: L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments

Supply Ability: 999

Get Best Price
Highlight:

20ms air flow controller

,

20ms flow rate controller

,

5v air flow controller

Analog Voltage Output (3):
1-5v
Zero Point Voltage:
0.95-1.05VDC
Supply Voltage (5):
8-24V
Maximum Operating Temperature Range:
25°C To + 85°C
Storage Temperature:
-40°C To 90°C
Flow Range Wide:
10,20,30,100,150,200,300,400,500For Reference
Analog Voltage Output (3):
1-5v
Zero Point Voltage:
0.95-1.05VDC
Supply Voltage (5):
8-24V
Maximum Operating Temperature Range:
25°C To + 85°C
Storage Temperature:
-40°C To 90°C
Flow Range Wide:
10,20,30,100,150,200,300,400,500For Reference
20ms Response Time Air Flow Controller Analog Output 1 To 5V

20ms Response Time Air Flow Controller Analog Output 1 To 5V 0

 

Product Description

CAFS4000 Series is made of microelectromechanical system (MEMS) flow sensor chip, suitable for various uses of clean, relatively dry gas measurement, to realize the digital, intelligent and improvement of high security, has the traditional industry innovation and promotion; wide range of flow range to meet the industry different equipment.

Flow measurement requirements, high sensitivity, high reliability, high stability and low cost performance characteristics can promote the industry to energy saving and intelligent exhibition.

CAFS4000 Series products are based on MEMS flow sensing unit, high precision digital processing and calibration circuit (MCU), integrated high resolution Δ - Σ A / D converter and internal calibration circuit and MCU processor to ensure the sensing signal real-time effective collection, obtain accurate flow signal,and in the corresponding compensation algorithm processing, so no external calibration compensation, can ensure high precision flow output; friendly digital output.

Message type, users can easily get the corresponding data information; the product application range is very broad.

 

 

Performance References

 

electrical character

Test conditions: VIN=12±0.01VDC, Ta=25°C. Relative humidity: 40% <relative humidity <60%

Maximum operating temperature range-25°C to + 85°C

  Flow range (1) Unit (2) Maximum flow rate (m/s)
CAFS4003V 0-12 SLM 0.527
CAFS4004V 0-20 SLM 0.877
CAFS4005V 0-35 SLM 1.535
CAFS4100V 0-50 SLM 2.193
CAFS4101V 0-100 SLM 4.387
CAFS4102V 0-150 SLM 6.58
CAFS4103V 0-200 SLM

8.773

 

CAFS4104V 0-300 SLM 13.16
 
specifications minimum give tacit consent to maximum unit
Analog voltage output (3) 1   5 VDC
Zero point voltage 0.95 1 1.05 VDC
zero drift 0.2 %F.S
Resolution (4) 0.1 %F.S
load 100
definition 2 3 %F.S
response time 1 3 mSec
Supply voltage (5) 8 12 24 VDC
supply current 30   20 mA
The overall material Silicon carbide, epoxy, PS, FR 4, silicon as seal