Send Message
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Gas Mass Flow Meter Controller Flow Meter > CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa

CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Certification: PTC23041812701C-CN01

Model Number: CAFS5012

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline conversation or face-to-face discussion

Delivery Time: 3-7 work days

Payment Terms: L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments

Supply Ability: 999

Get Best Price
Highlight:
Calibration Method:
Air At 20°C, 101.325 KPa
Methods Of Communication:
RS485Modbus
Interface:
NTP1/2”
Flow Range:
0-50/100/200/300/400slpmCustomizable
Calibration Method:
Air At 20°C, 101.325 KPa
Methods Of Communication:
RS485Modbus
Interface:
NTP1/2”
Flow Range:
0-50/100/200/300/400slpmCustomizable
CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa

 

 

Dimension

 

CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa 0

 

 

 

CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa

CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa is a high-performance, customizable gas flow measurement device designed for a diverse range of industrial, medical, and commercial applications. This series offers advanced features and customization options that differentiate it from other models, ensuring precise and reliable gas flow measurement for various industries.


Product Features

1. High Measurement Accuracy

CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa offers an accuracy of ±1.5% FS, providing reliable and precise measurements for accurate process control and monitoring.

2. Wide Flow Measurement Range

The series covers a broad flow range from 0-50 SLPM to 400 SLPM, with multiple selectable flow ranges of 50, 100, 200, 300, and 400 SLPM. This makes the CAFS5012 suitable for both low and high flow applications.

3. Customizable Response Time

With a base response time of 65 ms, the CAFS5012 allows for customization to 10, 20, 30, 50, 80, 100, 200 ms, catering to different measurement speed requirements and applications.

4. Advanced Communication Capabilities

The CAFS5012 supports RS485 Modbus communication, facilitating integration into complex control systems and enabling easy data collection and system management.

5. High Scale Ratio

The flow meter features an impressive 50:1 range ratio, accommodating a wide range of flow rates with a single device, providing versatility in measurement applications.

6. Flexible Output Options

The device offers 1-5 VDC analog output, allowing for easy connection to various data acquisition systems and ensuring compatibility with a range of monitoring and control setups.

7. Durable Construction

Constructed from stainless steel as standard, with aluminum alloy available upon request, the CAFS5012 is built for durability and resistance to harsh conditions.

8. High Pressure Capability

The CAFS5012 Series can handle up to 0.8 MPa of pressure, customizable based on specific requirements, making it suitable for demanding industrial processes.

9. Wide Temperature Range

Operating temperatures range from -10°C to 65°C, with storage temperatures from -25°C to 85°C, ensuring reliable performance across a wide range of environmental conditions.

10. High Protection Rating

With an IP40 protection level, the CAFS5012 is designed to function effectively in various industrial environments.

11. Reliable Calibration Method

The meter uses air at 20°C, 101.325 kPa for calibration, providing a standard and reliable basis for accurate measurements.

12. Easy Installation

Features NPT 1/2” connection threads for straightforward installation and integration into existing systems.

Performance Parameters

Feature CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa
Flow Range 0-50 / 100 / 200 / 300 / 400 SLPM (customizable)
Power Supply Voltage 8~24 VDC, 50 mA
Accuracy ±1.5% FS
Response Time 65 ms (customizable: 10, 20, 30, 50, 80, 100, 200 ms)
Maximum Pressure 0.8 MPa (customizable)
Communication Mode RS485 Modbus
Scale Ratio 50:1
Output Method Analog Outputs of 1-5 VDC
Temperature Range Medium Temperature: -10°C to 65°C<br> Ambient Temperature: -25°C to 85°C
Protection Level IP40
Calibration Method Air at 20°C, 101.325 kPa
Material Stainless Steel (Aluminum Alloy customizable)
Connection Mode NPT 1/2”

Applications

The CAFS5012 Series Mass Flow Meter is ideal for a variety of applications, including but not limited to:

  • Industrial Processes Used in manufacturing and production processes for precise gas flow measurement and control.

  • Medical Equipment Applied in medical devices and systems where accurate gas flow measurement is critical.

  • Petroleum Industry Utilized for gas flow measurement in oil and gas exploration, extraction, and processing.

  • Instrumentation Suitable for use in various scientific instruments and analytical devices.

  • Gas Measurement Ideal for measuring different types of gases in various industrial and commercial settings.

  • Chemical Processing Used in chemical production and processing to monitor and control gas flow.

  • Smelting Operations Applied in metal smelting processes for accurate measurement of gases.

  • Food Processing Used in the food industry for gas flow measurement in production and packaging processes.

  • Mechanical and Electrical Equipment Suitable for integration into mechanical and electrical systems requiring gas flow measurement.

Packing and Inspection

When opening the box, please follow these steps to ensure the product's condition and completeness:

  1. Check External Packaging
    Inspect the external packaging for any visible damage.

  2. Verify Contents
    Ensure the quantity and specifications of items match the packing list. Look for the following documents:

    • Packing List
    • Product Manual
    • Inspection Certificate
    • Wiring Diagram

Model and Specifications

Product Model Latus Rectum Joggle L H W D Specifications
CAFS 5012 12 NPT 1/2” 83 27 35 8 0-50 / 100 / 200 / 300 / 400 SLPM (L / MIN)