Send Message
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Digital Output Pressure Sensor > CPS137 Over Pressure 2X FS KPa Accuracy 70 To 115kPa Digital Output Pressure Sensor

CPS137 Over Pressure 2X FS KPa Accuracy 70 To 115kPa Digital Output Pressure Sensor

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Model Number: CPS137

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline contact or face-to-face discussion can be negotiated

Packaging Details: 3.3x3.3x2.85mm SMD

Delivery Time: 3-7 work days

Payment Terms: L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments

Supply Ability: 999

Get Best Price
Highlight:

70kPa Digital Output Pressure Sensor

,

115kPa Digital Output Pressure Sensor

,

digital output pressure transducer

Over Pressure:
2X FSkPa (bar)
Pressure Accuracy:
±0.2kPa (±2.0mbar) @ -20°C To +60°C, ±0.15kPa@25°C
LGA Package:
4 Lead
I2C Clock Frequency:
FC,I2C400kHz
Over Pressure:
2X FSkPa (bar)
Pressure Accuracy:
±0.2kPa (±2.0mbar) @ -20°C To +60°C, ±0.15kPa@25°C
LGA Package:
4 Lead
I2C Clock Frequency:
FC,I2C400kHz
CPS137 Over Pressure 2X FS KPa Accuracy 70 To 115kPa Digital Output Pressure Sensor

CPS137 Over Pressure 2X FS KPa (Bar) Accuracy 70 To 115kPa @25°C 70 To 115kPa (0°C To 50°C Verified)

 

Table 2: I2C COMMANDS

TYPE DESCRIPTION
Get Data (GD) Retrieves the sensor measurement data from the internal CPS137 registers*.
Measurement Request (MR) Wakes up the CPS137, performs a sensor measurement, stores the sensor measurement data in internal registers and returns to sleep

 

Electrical Parameters

Parameter Symbol Conditions Min Typ Max Units
Supply Current            
- Average Iavg VDD = 3V, one conversion/second   3.95   µA
- During Conversion Isc VDD = 3V, sensor active   1.5   mA
- Standby Iss VDD = 3V, sensor in standby mode     0.2 µA
Analog to Digital Converter            
- Resolution rADC     24   Bit
I²C Interface            
- Clock Frequency FC,I2C       400 kHz

Operating Conditions

Parameter Symbol Conditions Min Typ Max Units
Pressure Sensor            
- Range     30   130 kPa
      (300)   (1300) mbar
- Resolution       0.001   kPa
        (0.01)   mbar
- Accuracy   70 to 115kPa @ 25°C -0.15 ±0.10 +0.15 kPa
      (-1.5) (±1.0) (+1.5) mbar
    70 to 115kPa (0°C to 50°C) -0.2 ±0.15 +0.2 kPa
      (-2.0) (±1.5) (+2.0) mbar
- Solder Drifts     -0.1   +0.2 kPa
Temperature Sensor            
- Range     -40   85 °C
- Resolution       0.003   °C
- Accuracy   -40°C to 85°C -1 ±0.75 +1 °C
Operation            
- Supply Voltage to GND VSUPPLY   2 3.0 5.5 V
- Operating Temperature     -40   85 °C
- I²C Pull-Up Resistors RPU   1 2.2   kΩ

Absolute Ratings

Parameter Symbol Conditions Min Typ Max Units
Over Pressure   2X Full Scale       kPa
Supply Voltage (with respect to GND) VDD   -0.3   6.5 V
Voltages at Analog and Digital I/O Pins VA_IO, VD_IO   -0.3   VDD +0.3 V
Storage Temperature TSTOR   -60   150 °C