logo
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Pressure Sensor > CPS129 Small Form Factor 3 X 5 X 1.2mm High Performance Pressure Sensor

CPS129 Small Form Factor 3 X 5 X 1.2mm High Performance Pressure Sensor

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Model Number: CPS129

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline contact or face-to-face discussion can be negotiated

Delivery Time: 3-7 work days

Payment Terms: L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments

Supply Ability: 999

Get Best Price
Highlight:

High Performance Pressure Sensor

,

1.2mm Pressure Sensor

,

5mm air pressure sensor

Average Current Consumption:
<5uA (One Measurement)
Small Form Factor:
3 X 5 X 1.2mm (w X L X H)
Operating Temperature Range:
-40°C To +85°C
Pressure Relative Accuracy:
±0.01kPa(<1m)
Average Current Consumption:
<5uA (One Measurement)
Small Form Factor:
3 X 5 X 1.2mm (w X L X H)
Operating Temperature Range:
-40°C To +85°C
Pressure Relative Accuracy:
±0.01kPa(<1m)
CPS129 Small Form Factor 3 X 5 X 1.2mm High Performance Pressure Sensor

 

 

The CPS129 is a sophisticated, high-performance pressure sensor designed for a variety of advanced applications where accuracy, low power consumption, and robustness are crucial. Below is a comprehensive overview of the CPS129, highlighting its unique features and differentiating it from similar sensors in the market.

 

Features

  • Factory Calibrated Pressure and Temperature Sensor
  • Supply Voltage: 2V to 5.5V(3V @typical)
  • Average Current Consumption: <5uA (One Measurement)
  • Sleep State Current Consumption: <200nA (25°C)
  • Operating Temperature Range: -40°C to +85°C
  • Pressure Absolute Accuracy: ±0.1kPa (±1.0mbar) @ 0°Cto 50°C, 95kPa to 105kPa
  • Pressure Relative Accuracy: ±0.01kPa(<1m)
  • Temperature Accuracy: ±1.0°C

    Interfaces

  • I²C (up to 400kHz)

Physical Characteristics

  • Small Form Factor, 3 x 5 x 1.2mm (w x l x h)
  • LGA Package, 8 Lead
  • Top Side Sensing Port
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
PRESSURE SENSOR
Range    

30

(300)

 

120

(1200)

kPa

(mbar)

Resolution1       0.17   Pa
Noise in Pressure  

Full Bandwidth, Normal Mode

Altitude Based on Relative Pressure

 

1

10

 

Pa

cm

Accuracy  

30 to 120kPa

(-20°C to 0°C)

-0.2

(-2.0)

±0.17

(±1.7)

+0.2

(+2.0)

kPa

(mbar)

 

30 to 120kPa

(0°C to 65°C )

-0.15

(-1.5)

±0.10

(±1.0)

+0.12

(+1.2)

kPa

(mbar)

Solder Drifts     -0.1   +0.2 kPa
TEMPERATURE SENSOR
Range     -40   85 °C
Resolution       0.003   °C
Accuracy   -40°C to 85°C -1 ±0.75 +1 °C
OPERATION
Supply Voltage to GND2 VSUPPLY   2 3.0 5.5 V
Operating Temperature Range     -40   85 °C
I2C Pull-Up Resistors RPU   1 2.2   kΩ

1Guaranteed by design of 24bits ADC, and calculated according to the range in application.

2 Factory calibrated for Pressure and Temperature at 3.0V±10%. Output accuracy will be affected if used outside this range. Other ranges available upon request.