Product Details
Place of Origin: WUXI
Brand Name: Consensic
Certification: PTC23041812701C-CN01
Model Number: CMF5012
Payment & Shipping Terms
Minimum Order Quantity: Please contact us for details
Price: Offline contact or face-to-face discussion can be negotiated
Delivery Time: 3-7 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram/Alipay/business-to-business
Supply Ability: 1000
Levels Of Protection: |
IP40 |
Calibration Method: |
Air, And The 20℃,101.325kPa |
Response Time: |
65 (10,20,30,50,80,100,200, Etc.)ms Selectable |
Communication Mode: |
RS485Modbus |
Power Supply Voltage: |
8~24VDC,50mA VDC Selectable |
Flow Range: |
0-50/100/200/300/400 Slpm Customizable |
Levels Of Protection: |
IP40 |
Calibration Method: |
Air, And The 20℃,101.325kPa |
Response Time: |
65 (10,20,30,50,80,100,200, Etc.)ms Selectable |
Communication Mode: |
RS485Modbus |
Power Supply Voltage: |
8~24VDC,50mA VDC Selectable |
Flow Range: |
0-50/100/200/300/400 Slpm Customizable |
No.86, Dicui Road, Wuxi city, Jiangsu Province
Room 401, Floor 4, Building B5, North Gate of Taihu Zhigu Science and Technology Park
Tel.: + 86 510.85122279
E-mail: sales @consensic.com
■ High accuracy (1.5%F. S accuracy)
■ Linear output and no temperature compensation
■ Maintain long-term stability with minimal zero-drift
■ Quick response time
■ Flow range 0-60 m/s, 100g
■ Solid-state sensing core (no surface cavity or fragile film), resistance to blockage and pressure impact
■ Analog output (1 to 5 V) (digital I2C communication output is available)
■ Can be adapted to the relatively humid gas measurement
■ Operating temperature: -20°C to 65°C, storage temperature: -40°C to 85°C, humidity: 099% RH
■ The sensor is resistant to condensate water
Functional items | CMF5012 Medical Flow Sensors With Display Box Flow Range 0-60 M/S 100g | ||
performance parameter | unit | remarks | |
Flow range | 0-50/100/200/300/400 | slpm | customizable |
Power Supply Voltage | 8~24VDC,50mA | VDC | selectable |
accuracy | ±1.5 | % | FS |
response time | 65 (10,20,30,50,80,100,200, etc.) | ms | selectable |
maximum pressure | 0.8 | MPa | customizable |
communication mode | RS485 | Modbus | |
Measure the scale ratio | 50:1 |
Output method | Analog outputs of 1-5V | V | customizable |
temperature | Medium temperature (-10~65), ambient temperature (-25~85) | ℃ | |
joggle | NTP 1/2” | ||
levels of protection | IP40 | ||
Calibration method | Air, and the 20℃,101.325kPa | ||
The overall material | Stainless steel (aluminum alloy customizable) |