Send Message
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Medical Flow Sensors > High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors

High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Certification: PTC22072602101C-CN01

Model Number: CAFS6000

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline contact or face-to-face discussion can be negotiated

Delivery Time: 3-7 work days

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram/Alipay/business-to-business

Supply Ability: 1000

Get Best Price
Highlight:

5v medical flow sensors

,

high accuracy medical flow sensors

,

5V medical flow sensors

Maximum Voltage Output:
4.96 ~5.02V Linear
Maximum Operating Temperature Range:
-15°C To + 70°C
Response Time:
9~500ms Customizable
Calibration Conditions:
0℃, 1 Standard Atmosphere
Accuracy:
2%FS
Flow Range:
0~10000sccm Customizable Specifications
Maximum Voltage Output:
4.96 ~5.02V Linear
Maximum Operating Temperature Range:
-15°C To + 70°C
Response Time:
9~500ms Customizable
Calibration Conditions:
0℃, 1 Standard Atmosphere
Accuracy:
2%FS
Flow Range:
0~10000sccm Customizable Specifications
High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors

 

Fit & Install

 

1. Ensure that the sensor is not damaged and the wiring is complete;

2. When installing and connecting, the airflow direction is consistent with the sensor airflow indication direction, and the sensor lead line should be correctly connected according to the definition;

3. After confirming the correct connection, then connect the power supply to start work;

4. The sensor is connected to the power supply as far as possible after preheating for 2 minutes before use, better accuracy.

 

Performance Metrics

 

Test conditions: Vin = 12±0.1VDC, Ta=25°C. Relative humidity: 40% <relative humidity <60%.

Maximum operating temperature range-15°C to + 70°C

specifications

High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors

least value normal value crest value unit remarks
Flow range 0

 

10000 sccm Customizable specifications
service voltage 8-24V V customizable
current 50 mA  
Maximum voltage output 4.96 5 5.02 V linear
Zero point voltage output 0.98 1 1.02 V linear
accuracy   1.5 2 %FS  
repetitiveness   ±0.3   %  
resolution ratio   0.1   % gamut
withstand voltage   0.3 0.5 MPa customizable
response time 9 65 500 ms customizable
zero drift   0.2   %Year gamut
Calibration conditions 0℃, 1 standard atmosphere
The overall material Silicon carbide, epoxy resin, PPS, and silicon shall serve as the sealing material