CMF9019 Nominal Diameter 19mm Power Supply 8-24VDC 50mA VDC Flowmeter

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Certification: PTC23091116101C-CN01

Model Number: CMF9019

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline conversation or face-to-face discussion

Delivery Time: 3-7 work days

Payment Terms: L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments

Supply Ability: 999

Get Best Price
Highlight:

24V Flowmeter

,

50mA Flowmeter

,

8V air flow meter sensor

Nominal Diameter (mm):
19
Maximum Flow Specification Selection:
100,200,300,500,600,800,1000(SLPM)
Display Mode:
Instantaneous Flow: SLPM; Cumulative Flow: SL
Working Humidity:
<100% RH (no Ice, No Condensation)
Nominal Diameter (mm):
19
Maximum Flow Specification Selection:
100,200,300,500,600,800,1000(SLPM)
Display Mode:
Instantaneous Flow: SLPM; Cumulative Flow: SL
Working Humidity:
<100% RH (no Ice, No Condensation)
CMF9019 Nominal Diameter 19mm Power Supply 8-24VDC 50mA VDC Flowmeter

CMF9019 Nominal Diameter 19mm Power Supply 8-24VDC 50mA VDC Flowmeter 0

Output Pin Definition

Pin Number User Input/Output Interface Wire Color (Reference)
1 Power Positive (+) Red
2 Power Negative (-) Black
3 485A Blue
4 485B Green
5 VOUT (Analog Voltage Output) Yellow
6 4-20mA Brown
7 Power Negative (-) White

 

User Input/Output Interface Notes

 

RS485 communication uses pins 3 (A) and 4 (B).

Power positive (Pin 1) requires external power input (8~24VDC).

Analog voltage output (1-5VDC) is provided on Pin 5 (Yellow).
Power negative (GND) is common for Pins 2 and 7.

Model Comparison Table

Model Nominal Diameter (mm) Maximum Flow Specification (SLPM) Remarks
CMF9019 19 100, 200, 300, 500, 600, 800, 1000 -

Performance Parameters

Functional Item CMF9019 Nominal Diameter 19mm Power Supply 8-24VDC 50mA VDC Flowmeter
Specifications CMF9019
Nominal Diameter 19 mm
Turndown Ratio 100:1
Power Supply 8~24VDC, 50mA (customizable)
Accuracy ±1.5% Full Scale (FS)
Repeatability 0.25%
Response Time 67 ms (default, customizable)
Maximum Pressure 0.5 MPa (customizable to 0.8 MPa)
Communication Mode RS485 (MODBUS)
Output Modes Analog Output 1-5 VDC, 4-20mA (optional)
Display Mode Instantaneous Flow: SLPM; Cumulative Flow: SL
Temperature Medium: -10~65°C, Ambient: -25~85°C
Operating Humidity <100% RH (no ice, no condensation)
Weight 0.395 kg
Interface G3/4” (customizable)
Calibration Conditions Air, 20°C, 101.325 kPa