Send Message
Wuxi Consensic Electronic Technology Co., Ltd.
products
products
Home > products > Sensor > CAFS6000 Voltage Input (Vin): 12 ± 0.1 VDC Ambient Temperature (Ta): 25°C

CAFS6000 Voltage Input (Vin): 12 ± 0.1 VDC Ambient Temperature (Ta): 25°C

Product Details

Place of Origin: WUXI

Brand Name: Consensic

Certification: PTC22072602101C-CN01

Model Number: CAFS6000

Payment & Shipping Terms

Minimum Order Quantity: Please contact us for details

Price: Offline contact or face-to-face discussion can be negotiated

Delivery Time: 3-7 work days

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram/Alipay/business-to-business

Supply Ability: 1000

Get Best Price
Highlight:
Accuracy:
2%FS
Calibration Conditions:
0℃, 1 Standard Atmosphere
Maximum Voltage Output:
4.96 ~5.02V Linear
Maximum Operating Temperature Range:
-15°C To + 70°C
Response Time:
9~500ms Customizable
Flow Range:
0~10000sccm Customizable Specifications
Accuracy:
2%FS
Calibration Conditions:
0℃, 1 Standard Atmosphere
Maximum Voltage Output:
4.96 ~5.02V Linear
Maximum Operating Temperature Range:
-15°C To + 70°C
Response Time:
9~500ms Customizable
Flow Range:
0~10000sccm Customizable Specifications
CAFS6000 Voltage Input (Vin): 12 ± 0.1 VDC Ambient Temperature (Ta): 25°C

Fit & Install Instructions:

  1. Initial Check:Ensure the sensor is undamaged.Verify that the wiring is complete.
  2. Installation and Connection:Align the airflow direction with the sensor's airflow indication direction.Connect the sensor lead line correctly based on the wiring definition.
  3. Power Connection:Confirm the correct connection before proceeding.Connect the power supply to initiate operation.
  4. Preheating for Accuracy:For optimal accuracy, preheat the sensor for 2 minutes by connecting it to the power supply.

Performance Metrics:

  • Test Conditions:Voltage Input (Vin): 12 ± 0.1 VDC.Ambient Temperature (Ta): 25°CRelative Humidity: 40% < relative humidity < 60%
  • Maximum Operating Temperature Range: -15°C to +70°C

 

Specifications:

Parameter Least Value Normal Value Crest Value Unit Remarks
Flow Range 0 10000   sccm Customizable
Service Voltage   8-24V   V Customizable
Current   50   mA  
Maximum Voltage Output 4.96 5 5.02 V Linear
Zero Point Voltage Output 0.98 1 1.02 V Linear
Accuracy 1.5 2   %FS  
Repetitiveness ±0.3     %  
Resolution Ratio   0.1   % gamut  
Withstand Voltage 0.3 0.5   MPa Customizable
Response Time 9 65 500 ms Customizable
Zero Drift   0.2   %Year gamut
Calibration Conditions   0℃, 1 standard atmosphere      
Overall Material   Silicon carbide, epoxy resin, PPS, and silicon   Sealing materials  

Maximum Ratings:

  • Operating Temperature: -15°C to 70°C
  • Storage Temperature: -25°C to 85°C
  • Humidity: 0% to 100% RH
  • Weight: 100 g
  • Resistance: The sensor is resistant to condensate water.